Factor Information
Data ID 2306
Factor Cardiopulmonary exercise test: Ve/Vo2 slope--In Relation to Lung Function
Description Moderate to severe impairment of lung function related to complexity of underlying cardiac defect, enlarged cardiothoracic ratio, previous thoracotomy/ies, body mass index, scoliosis, and diaphragm palsy.
Biomarker NA
Classification E10 (physiological factor - other)
Association
Application prognosis
Objective We investigated the prevalence of abnormal lung function, its relation to severity of underlying cardiac defect, its surgical history, and its impact on outcome across the spectrum of adult congenital heart disease.
p Value <0.01
Conclusion Moderate to severe impairment of lung function related to complexity of underlying cardiac defect, enlarged cardiothoracic ratio, previous thoracotomy/ies, body mass index, scoliosis, and diaphragm palsy.
Risk Factor unknown
CHD Type
ID 595
CHD Type isolated CHD/non-isolated CHD
CHD Subtype ASD/VSD/AC/TGA/AVSD/ccTGA/EA/TOF/other
Reference
PMID 23382015
Year 2013
Title Abnormal lung function in adults with congenital heart disease: prevalence, relation to cardiac anatomy, and association with survival.
Sample
Population Adults
Source a retrospective study
Region London,UK
Method collect and classify
Race Europe
Disease History N/A
Treatment History Surgical repair/palliation
Group Moderately to Severely Impaired of lung function(Treatment) Normal(Control)
Number 353 628
Age 32.7±13.2 years 33.7±12.8 years
Gender (Male: Female) 193:160 349:279
Marker Level 40.1±16.5 35.1±13.8