Factor Information
Data ID 391
Factor predicted peak VO2
Description Peak VO2 averaged predicted was lower than controls on univariable analysis
Biomarker NA
Classification E11 (physiological factor - physical sign)
Association
Application prognosis
Objective Peak VO2 averaged predicted was lower than controls on univariable analysis
p Value 0.004
Conclusion Peak VO2 averaged only 50.1% ± 13.5% predicted (15.5 ± 5.2 ml/kg/min) and was lower than controls on univariable analysis
Risk Factor unknown
CHD Type
ID 53
CHD Type isolated CHD
CHD Subtype TOF
Reference
PMID 30216689
Year 2018
Title Exercise testing and spirometry as predictors of mortality in congenital heart disease: Contrasting Fontan physiology with repaired tetralogy of Fallot.
Sample
Population Adults
Source a retrospective study
Region Boston, USA
Method reviewed
Race North America
Disease History N/A
Treatment History N/A
Group TOF index cases(Treatment) TOF control cases(Control)
Number 15 (TOF cases) 45 (TOF controls)
Age 42.0 ± 15.3 years 41.6 ± 14.6 years
Gender (Male: Female) 9:6 24:21
Marker Level 50.1±13.5% 68.5 ± 15.0%