Factor Information
Data ID 482
Factor transposition of great arteries(TGA)
Description Predictors of acute radiofrequency catheter ablation(RF) failure were as follows: nonrelated cavotricuspid isthmus IART, previous atrial fibrillation.
Biomarker NA
Classification A3 (clinical factor - disease & symptom)
Association
Application Prognosis
Objective Predictors of acute radiofrequency catheter ablation failure
p Value <0.05
OR >4.0
Conclusion Although ablation in CHD is a challenging procedure, acute success of 75% can be achieved in moderate–highly complex CHD patients in a referral center. Predictors of failed ablation are IART different from cavotricuspid isthmus, previous atrial fibrillation, and markers of complex CHD (transposition of great arteries, systemic ventricle dilation).
Risk Factor risk factor
CHD Type
ID 460
CHD Type isolated CHD/non-isolated CHD
CHD Subtype TOF/ASD/SV/SPF/other/VSD/ASD/EA/CHD with IART
Reference
PMID 29602766
Year 2018
Title Predictors of Acute Failure Ablation of Intra-atrial Re-entrant Tachycardia in Patients With Congenital Heart Disease: Cardiac Disease, Atypical Flutter, and Previous Atrial Fibrillation.
Sample
Population N/A
Source Clinical data
Region Barcelona, Spain
Method observational study
Race Europe
Disease History N/A
Treatment History IART radiofrequency catheter ablation
Group RFCA Failed(Treatment) RFCA Success(Control)
Number 13(Total: 24) (with TGA) 12(Total: 70) (with TGA)
Age 39.4±15.3 years 35.5±14.7 years
Gender (Male: Female) N/A N/A
Marker Level 0.542 0.171