Factor Information
Data ID 89
Factor Prior surgical maze (Predictors of Recurrence After First Catheter Ablation)
Description Univariate predictors of AT recurrence included Fontan status, prior surgical maze procedure, and pre-procedural failure of amiodarone therapy
Biomarker YES
Classification A12 (clinical factor - treatment)
Association
Application diagnosis
Objective To access a negative predictor of AT-free survival
p Value 0.03
HR 3.34
Conclusion Prior maze procedure was a negative predictor of AT-free survival.
Risk Factor risk factor
CHD Type
ID 413
CHD Type isolated CHD
CHD Subtype ASD, VSD/AS, BAV/TOF, PS/AVC/ECD/EA/other
Reference
PMID 31000097
Year 2019
Title Catheter Ablation for Atrial Tachycardia in Adults With Congenital Heart Disease: Electrophysiological Predictors of Acute Procedural Success and Post-Procedure Atrial Tachycardia Recurrence
Sample
Population Adults
Source chart and procedure report
Region Columbia, United States
Method a retrospective study
Race North America
Disease History ATs [Of the AT, 179 (93%) were intra-atrial macro-re-entrant tachycardia, and 12 (7%) had a focal origin.]
Treatment History Underwent catheter ablation for 182 AT; medians includes amiodarone(22), sodium channel blockers(1), beta-bolckers(78), sotalol(14), calcium-channel blockers(8).
Group N/A(Treatment) N/A(Control)
Number 8(total:140) 132(total:140)
Age N/A N/A
Gender (Male: Female) N/A N/A
Marker Level N/A N/A